Schneider Electric LC1F800 Contactor body without coil, TeSys F, 3P(3NO), AC-3 <=440V 800A
Schneider Electric
LC1F800
Contactor body without coil, TeSys F, 3P(3NO), AC-3 <=440V 800A
MPN: LC1F800
PPN: SCH-LC1F800
Spec sheet
Loading compare button...
In Stock
Company Stock:
00
Lead times may vary. For an accurate estimate please contact us.
Loading dialog...
Looking to buy a large quantity?
To view product inventory
Description
TeSys F contactor, 3 poles (3NO), 800A/1000V AC-3, for motor applications up to 450kW@400V. Contactor with no coil to allow a later selection and installation (coil to be ordered separately), it provides bolt terminals for bars or cables with lugs. For high operating rates until 600 cycles/hour and environments until 55°C, it procures high reliability and durability. It makes installation and maintenance easy thanks to a drawer for insertion of the selected coil and a large choice of add-on blocks and accessories (to be ordered separately). Multi standards certified (IEC, UL, CSA, CCC, Marine), Green Premium compliant (RoHS/REACh).
StandardsIEC 60947-1, JIS C8201-4-1, EN 60947-1, IEC 60947-4-1, EN 60947-4-1
Complementary Attributes
Control Circuit Voltage Limits
drop-out: 0.3...0.5 Uc DC with LX4 coil, operational: 0.85...1.1 Uc AC 40...400 Hz with LX1/LX9 coil, drop-out: 0.3...0.5 Uc AC 40...400 Hz with LX1/LX9 coil, operational: 0.85...1.1 Uc DC with LX4 coil, operational: 85...275 V AC 50/60 Hz with LXE coil, drop-out: 0...60 V AC 50/60 Hz with LXE coil, operational: 85...418 V DC with LXE coil, drop-out: 0...45 V DC with LXE coil
Ie Rated Operational Current
1000 A 40 °C) <= 440 V AC AC-1, 800 A 55 °C) <= 440 V AC AC-3
Ue Rated Operational Voltage
<= 1000 V AC 50/60 Hz, <= 1000 V AC 50/60 Hz, <= 1000 V AC 50/60 Hz, <= 460 V DC, <= 460 V DC, <= 1000 V AC 50/60 Hz, <= 1000 V AC 50/60 Hz, <= 1000 V AC 50/60 Hz, <= 460 V DC, <= 460 V DC
Irms Rated Making Capacity
8000 A AC conforming to IEC 60947-4-1
Rated Breaking Capacity
6400 A conforming to IEC 60947-4-1
Icw Rated Short Time Withstand Current2600 A 40 °C - 3 min, 5500 A 40 °C - 10 s, 4600 A 40 °C - 30 s, 3600 A 40 °C - 1 min, 1700 A 40 °C - 10 min
Uc Control Circuit Voltage110...400 V AC 40...400 Hz with LX1/LX9 coil, 110...400 V DC with LX4 coil, 100...250 V AC 50/60 Hz with LXE coil, 100...380 V DC with LXE coil
Ui Rated Insulation Voltage1000 V IEC 60947-4-1, 1500 V VDE 0110 group C
Maximum Operating Rate600 cyc/h 55 °C
Uimp Rated Impulse Withstand Voltage8 kV
Important Information Attributes
Persona Type Ids
EU, OM, OM8, PB
Market Segmentation Id
COMMERCIAL, INDUSTRIAL
Associated Fuse Rating
1000 A gG at <= 440 V, 800 A aM at <= 440 V
Heat Dissipation
25-25 W, 2.2-5.5 W
Inrush Power In Va
1700-1700 VA, 40...400 Hz cos phi 0.9 (at 20 °C)with LX1/LX9 coil, 1900-1900 VA (at 20 °C)with LX4 coil, 460-730 VA, 50/60 Hz cos phi 0.5 (at 20 °C)with LXE coil, 500-680 VA cos phi 0.5 (at 20 °C)with LXE coil
Motor Power Kw
450 kW at 1000 V AC 50/60 Hz (AC-3), 450 kW at 500 V AC 50/60 Hz (AC-3), 475 kW at 660...690 V AC 50/60 Hz (AC-3), 110 kW at 400 V AC 50/60 Hz (AC-4), 450 kW at 380...400 V AC 50/60 Hz (AC-3), 450 kW at 415 V AC 50/60 Hz (AC-3), 450 kW at 440 V AC 50/60 Hz (AC-3), 250 kW at 220...240 V AC 50/60 Hz (AC-3)
Power Dissipation Per Pole
120 W AC-1, 77 W AC-3
Utilisation Category
AC-3, AC-1, AC-4
Icw Rated Short Time Withstand Current
2600 A 40 °C - 3 min, 5500 A 40 °C - 10 s, 4600 A 40 °C - 30 s, 3600 A 40 °C - 1 min, 1700 A 40 °C - 10 min
Carbon Footprint Of The Distribution Phase A4
6.221816136, 6 kg CO2 eq.
Carbon Footprint Of The Installation Phase A5
0 kg CO2 eq., 0.049997823
Carbon Footprint Of The Use Phase B2 B3 B4 B6
6 328 kg CO2 eq., 6327.86174
Local Data Status
Publishable
Global Commercial Status
End of commercialisation
Stocking Flag
N
Serviceability
No
Field Service Division
PPIBS
Legacy Weee Scope
In
Eoli Availability Display
Yes
Reach Full Compliance Status
Reference contains Substances of Very High Concern above the threshold
Reach Compliance Directive
Reference contains Substances of Very High Concern above the threshold
Rohs Eur Status
Compliant By Exemption
China Rohs In Scope
No
Without Single Use Plastic
No
Function Option Id
STANDARD
Product Kit Identifier
N
Compatibility Code
LC1F
Energy Efficiency Optimized
False
Mounting Support
plate
Pole Contact Composition
3 NO
Product Availability
Stock - Normally stocked in distribution facility
Product Or Component Type
contactor
Range
TeSys
Returnability
Yes
Sustainable Packaging
No
Weee Label
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Pep Code
ENVPEP1505009EN
Pep Verification Date
2024-05-01
Psr Version
PSR-0005-ed3-EN-2023 06 06
Data Source
extrapolated product
Functional Unit Unit
unit
Energy Model Installation A5 2
Electricity Mix; Low voltage; 2018; China, CN
Energy Model End Of Life C1 C4 2
Electricity Mix; Low voltage; 2018; China, CN
Width Nominal
309 mm
Persona Type NamesEnd User, Original Equipment Manufacturer, OEM - Control Panelbuilder, Panel Builder
Hold In Power Consumption In Va12-12 VA, 40...400 Hz cos phi 0.9 (at 20 °C)with LX1/LX9 coil, 12-12 VA (at 20 °C)with LX4 coil, 7-10 VA, 50/60 Hz cos phi 0.5 (at 20 °C)with LXE coil, 4.0-5.5 VA cos phi 0.5 (at 20 °C)with LXE coil
Mechanical Robustnessvibrations contactor open2 Gn, 5...300 Hz, vibrations contactor closed4 Gn, 5...300 Hz, shocks contactor open6 Gn for 1/2 sine wave (11 ms), shocks contactor closed15 Gn for 1/2 sine wave (11 ms)
Operating Time60...80 ms closing with LX1/LX9 coil, 160...180 ms opening with LX1/LX9 coil, 60...80 ms closing with LX4 coil, 40...50 ms opening with LX4 coil, 40...80 ms closing with LXE coil, 6...54 ms opening with LXE coil
Tightening Torquepower circuit 58 N.m, control circuit 1.2 N.m
Connections Terminalscontrol circuit screw clamp terminals 1 1-4 mm²flexible with cable end, control circuit screw clamp terminals 1 1-4 mm², control circuit screw clamp terminals 2 1-4 mm², power circuit bar 2 60 x 5 mm, power circuit bolted connection, control circuit screw clamp terminals 1 1-4 mm²flexible without cable end, control circuit screw clamp terminals 2 1-4 mm²flexible with cable end, control circuit screw clamp terminals 2 1-2.5 mm²solid without cable end
Ie Rated Operational Current1000 A 40 °C) <= 440 V AC AC-1, 800 A 55 °C) <= 440 V AC AC-3
Carbon Footprint Of The End Of Life Phase C1 To C435.86653442, 36 kg CO2 eq.
Carbon Footprint Of The Manufacturing Phase A1 To A3114 kg CO2 eq., 114.0341391
Medium DescContactor body without coil, TeSys F, 3P(3NO), AC-3 <=440V 800A
Local Publishable Date2024-11-02
Return IndicatorY
Device TypeLV equipment - LV contactor
TraceabilityNo
Average Life Duration20 year(s)
Scope PerimeterAt least in Europe
End Of Life Doc RefENVEOLI1505009EN
Reach Full Compliance Status IdCONTAINS_SVHC
Rohs Eur In ScopeYes
Rohs Eur Full Compliance StatusCompliant By Exemption
With Recycled CardboardYes
Product Contributes To Saved And Avoided EmissionsNo
Function OptionStandard
Average Impedance0.12 mOhm - Ith 1000 A 50 Hz
Device Short NameLC1F
Mechanical Durability5 Mcycles
Overvoltage CategoryIII
Poles Description3P
Product NameTeSys F
Protective TreatmentTH
Range Of ProductTeSys F
Software Versionv6.1
Total Lifecycle Carbon Footprint6 484 kg CO2 eq.
Ith Conventional Free Air Thermal Current1000 A (at 40 °C)
Database Version2023-02
Pcr VersionPCR-4-ed4-EN-2021 09 06
Type Of Verification For The PepIndependent internal review
Functional Unit DescriptionEstablish and cut off the supply of a downstream installation from an electrical and/or mechanical control characterised by the composition of the poles or type of contacts X, a rated voltage of Ue, a rated current Ie, a control circuit voltage Uc, with Np poles, and if applicable the specific specifications, in the Household/Commercial or Industrial application areas, according to the appropriate use scenario, and during the reference service life of the product of 20 years
Energy Model Manufacturing A1 A3 2China, CN
Energy Model Use B6 2Electricity Mix; Low voltage; 2018; China, CN
Height Nominal304 mm
Environment Attributes Main
China Rohs Regulation
Product out of China RoHS scope , Product out of China RoHS scope. Substance declaration for your information.
Permissible Ambient Air Temperature Around The Device
-5-55 °C, -5-55 °C
Recycled Metal Content At Cr Level
0 %
Carbon Footprint
6484.034227
Ambient Air Temperature For Storage
-60-80 °C
Environmental Disclosure
ENVPEP1505009EN
Operating Altitude
9842.52 ft (3000 m) without derating
Packaging Without Single Use Plastic
No
Pep Code
ENVPEP1505009EN
Pcr Version
PCR-4-ed4-EN-2021 09 06
Type Of Verification For The Pep
Independent internal review
Ip Degree Of ProtectionIP20 front face with shrouds IEC 60529, IP20 front face with shrouds VDE 0106
Take BackNej
Mercury FreeYes
Ambient Air Temperature For Operation-5-55 °C
Circularity ProfileENVEOLI1505009EN
Eu Rohs DirectiveCompliant By Exemption
Packaging Made With Recycled CardboardYes
Reach RegulationReference contains Substances of Very High Concern above the threshold
Pep Verification Date2024-05-01
Psr VersionPSR-0005-ed3-EN-2023 06 06
General Attributes
Product Or Component Type
contactor
Range Of ProductTeSys F
ETIM
ETIM 8
EC000066
ETIM 9EC000066
Contractual Warranty Attributes
Warranty Period
18 months
Warranty18 months
Specifications
Country of Origin
United States
Depth255 mm
Downloads
Downloads
Similar Products
Leviton 2610 30 Amp 125 Volt Flush Mount Locking Receptacle, NEMA L5-30R, Nylon Body
MPN
2610
In Stock
Company Stock:
00
CAD$28.64/EA
Qty:
Add to Cart
Killark OTB-3CG O/Duraloy 5 Conduit Body with Cover And Gasket- TB Type - Hub Size 1",12.0 cu in